🔔🔔6000W laser cleaning machine adjusting red light
📢📢The disassembly and assembly process needs to be carried out in a clean environment. When removing and installing the lenses, dust-free gloves or dust-free finger covers must be worn.
💎First, seal the light-emitting port with masking tape and check the position of the red light deviation.
💎Then loosen the screws that fix the motor.
💎Loosen the screws and then gently rotate the motor to adjust the red light to the middle position.
✨Use a caliper to measure whether the two sides of the red light are of the same width.
✨If they are different, then gently rotate the motor to adjust.
✨After the adjustment is complete, simply tighten the motor fixing screws.
Foster Laser
+86 153 1415 5887
www.fosterlaser.com
https://www.fosterlaser.com/